Boiler Technician and Boiler Repair in Bilajari: Flame Keeps Going Out

Completed work

Boiler Technician and Boiler Repair in Bilajari: Flame Keeps Going Out

Boiler technician and boiler repair services in Bilajari. Diagnosis of a problem where the boiler ignites normally but the flame frequently goes out during operation, the unit repeatedly attempts to restart, and the temperature remains unstable. Cleaning and inspection of the ionization electrode.

A customer in Bilajari requested boiler repair because the flame frequently went out while the boiler was operating. According to the customer, the boiler ignited normally after startup and began heating the radiators. However, after several minutes, the flame suddenly went out, and after a short pause, the unit attempted to ignite again. This happened several times throughout the day, causing the radiator temperature to remain unstable. After gathering the initial information, a suitable boiler technician was sent to the address.

The boiler technician first checked the system pressure, gas ignition, and operation of the boiler in heating mode. The water pressure was within the normal range, and the boiler ignited without any problems during the initial startup. However, after operating for some time, the control system occasionally failed to detect the flame correctly and shut off the gas supply as a safety measure.

During a detailed diagnosis, the boiler technician inspected the ignition system, ionization electrode, gas valve, electronic control board, and electrical connections. Dirt and oxidation caused by prolonged operation were found on the surface of the ionization electrode. This buildup prevented the electrode from detecting the flame consistently. As a result, the electronic control system occasionally interpreted the situation as a loss of flame and automatically shut off the gas supply.

During the boiler repair, the unit was safely disconnected from the electricity and gas supply. The boiler technician removed the ionization electrode, cleaned its surface, and checked its condition and correct positioning relative to the burner. The electrode cable, connection points, and connection to the electronic control board were also inspected. The electrode itself was still in working condition, so replacement was not necessary. No additional faults were found in the gas valve or other ignition components.

After the repair was completed, the boiler was restarted and tested at different temperature settings. The boiler technician confirmed that the flame remained stable, the unit no longer shut down without reason, and repeated ignition attempts had stopped. The radiators heated normally. The domestic hot water mode was also tested separately, and the boiler operated steadily in both modes.

The work was completed in approximately 1.5 hours. The customer was advised to contact a technician if the boiler ignites normally but the flame goes out after several minutes, the unit frequently attempts to reignite, or the temperature becomes unstable. These symptoms may be related to the ionization electrode, gas system, electronic control system, or other ignition components.

In Bilajari and surrounding areas, services are available for boiler technician, boiler repair, boiler flame keeps going out, boiler frequently shuts off and reignites, boiler does not detect the flame, ionization electrode cleaning, boiler ignition system repair, boiler operates inconsistently, and other boiler repair services.